Preparing your datasheet

BRF 900/…-125

Band-Pass/Band-Reject Filters for the 900 MHz Band
Description
  • High power base station band-reject filters for the 890 – 960 MHz range.
  • The use of large ø125 mm cavities means a high Q,
    resulting in a very narrow notch bandwidth.
  • The large dimensions also mean a high power rating.
  • Unloaded Q of a single cavity is approx. 4500.
  • High frequency stability on temperature and power.
  • 19” mounting brackets are available as an option.
Specification
Electrical
Model
BRF 900/1-125BRF 900/2-125BRF 900/3-125
Frequency 890 – 960 MHz
Max. Input Power
300 W @ 0.5 dB IL
175 W @ 1.0 dB IL
300 W @ 1.0 dB IL
175 W @ 2.0 dB IL
300 W @ 1.5 dB IL
175 W @ 3.0 dB IL
1 dB Notch Bandwidth 1 % of fc
Impedance 50 Ω
VSWR < 1.5:1
Environmental
Frequency Stability 1.5 ppm/° C (approx.)
Operating temperature range -30 °C to +60 °C
Mechanical
Connection(s) N(f)
Historic Brand Procom
Dimensions
ø125 x 200 mm / ø4.92 x 7.87 in.L:125 x W:250 x H:200 mm / L:4.92 x W:9.84 x H:7.87 in.L:125 x W:375 x H:200 mm / L:4.92 x W:14.76 x H:7.87 in.
Weight
Approx. 0.7 kg / 1.54 lb.Approx. 1.5 kg / 3.31 lb.Approx. 2.5 kg / 5.51 lb.
Ordering Codes
Model Product No. Model

BRF 900/1-125

200001601 BRF 900/1-125

BRF 900/2-125

200001946 BRF 900/2-125

BRF 900/3-125

200001947 BRF 900/3-125
PROCOM A/S reserves the right to amend specifications without prior notice
PROCOM A/S • Smedetoften 12 DK 3600 Frederikssund • Denmark
Generated : 2026-06-24 Version 1