PRO-DAR
Receiver Multicoupler family with redundant amplifier system for the VHF & the low UHF range 30 – 960 MHz.
Description
- Active Receiver multicouplers PRO-DAR (Dual Amplifier RMC) comes with 1 antenna input and 4 or 8 receiver outputs. The PRO-DAR’s with 12 or 16 outputs are under development.
- Allows a number of receivers to share the same antenna without interaction and loss of signal.
- Coves the whole frequency range 30 to 960 MHz.
- If only a smaller frequency range is desired, a preselector filter can be built in to prevent possible interference from strong transmitters outside the frequency band of interest. Amphenol Procom offer a wide range of both band selective and narrow-band low-loss filters suitable for preselector use.
- Please refer to the preselector overview and specify frequency range when ordering.
- The build-in ultra-high dynamic range amplifiers ensure outstanding multicoupler linearity and high reject of distortion products.
- Low amplifier noise figure ensures lowest possible S/N deterioration of the received and distributed RF signals.
- Redundant amplifier design with two identical amplifier stages coupled in parallel ensures maximum operational reliability.
- If a fault occurs in one amplifier stage,the amplifier will continue to operate with gain around -6 dB relative to the normal gain providing uninterrupted service with only minor performance deterioration.
- High isolation between receiver outputs ensure insignificant low mutual coupling between the connected receivers.
- Operates on 230 V AC or 115 V AC mains supply or 12 V, 24 V or 48 V DC supply (Depending on type, see ordeing designations)
- Galvanically isolated power supply with floating power supply input prevents unwanted ground loops and ensures operation on DC voltage systems with both + and – to ground.
- Power supply backup function provides automatic switching to DC supply if the AC mains supply fails, ensuring uninterrupted service of the multicoupler.
- POWER ON/operating status LED on front.
- Supply voltage/current monitoring alarm circuitry with floating relay switch-over alarm contact. If a fault occurs, in the RF amplifer circuitry, the alarm circuitry immediately toggles the relay to indicate fault condition and change the POWER on/operating status LED from constant green light to flashing red light.
- If both mains AC supply and DC supply fail, the multicoupler is completely de-energized, the relay will also be toggled to indicate fault condition. The POWER ON / operating status LED will then be off in this situation.
- Mains supply connector: IEC type fitted with noise filter.
- DC power supply connector: Pluggable terminal block/header fitted with noise filter.
- Alarm connector: Pluggable terminal block/header.
- RF connectors: N-female on all ports (other types on request).
- Comes as standard with black powder lacquered front plate
- 19” rack module housing
- PRO-DAR4 & PRO-DAR8: 1HU
- PRO-DAR12 & PRO-DAR16: 2HU (Under development)
- Please Note:
- Power cable is not included. Must be ordered separately, see Accessories.
Specification
|
Electrical
|
|
Power Supply
|
230 V AC models : 198 to 264 V AC 47 – 63 Hz / Max. 0.16 A 115 V AC models : 99 to 132 V AC 47 – 63 Hz / Max. 0.32 A |
|
Model
|
PRO-DAR4 & PRO-DAR8PRO-DAR12 & PRO-DAR16 (Ask for availability)
|
|
Gain (Input To All Outputs)
|
2 dB nominal |
|
Frequency
|
30 – 960 MHz |
|
Gain variance
|
< ±2.0 dB |
|
Max. Output Power @ 1 dB Compression (P1dB)
|
> 10 dBm |
|
Noise Figure, Amplifier
|
30 – 520 MHz : < 3.0 dB 520 – 960 MHz : < 3.5 dB |
|
Output 3. Order Intercept point (OIP3)
|
30 – 520 MHz : > 30 dBm 520 – 960 MHz : > 25 dBm |
|
Impedance
|
50 Ω |
|
Output 2. Order Intercept point (OIP2)
|
> 45 dBm |
|
Max. Input Power (dBm)
|
23 dBm |
|
Isolation between outputs
|
30 – 100 MHz : > 20 dB 100 – 400 MHz : > 27 dB 400 – 960 MHz : > 20 dB |
|
Input VSWR
|
≤ 2.0:1 |
|
Input-Output Isolation
|
> 30 dB |
|
Effective Noise Figure all outputs
|
< 5 dB |
|
Output VSWR
|
≤ 1.5:1 |
|
DC Supply, 12 V DC types
|
10.8 to 14.4 V DC / 600 mA |
|
DC Supply, 24 V DC types
|
20 to 33 V DC / 600 mA |
|
DC Supply, 48 V DC types
|
40 to 60 V DC / 125 mA |
|
No. of channels
|
4 or 812 or 16
|
|
Environmental
|
|
Operating temperature range
|
-10 °C to +60 °C |
|
Humidity
|
< 90% non-condensing |
|
Mechanical
|
|
Power Connector
|
3-terminal IEC60320-1 C14 (m) |
|
Connection(s)
|
N(f) (standard) BNC(f), TNC(f) or SMA(f), please contact for availability |
|
DC Connector
|
3-pole Phoenix terminal block/header |
|
Historic Brand
|
Amphenol Procom |
|
Dimensions
|
PRO-DAR4 & PRO-DAR8 : 19″ x 1HU x 261 mm (482.6 x 44.45 x 261 mm) / (19.02 x 1.75 x 10.28 in.)PRO-DAR12 & PRO-DAR16 : 19″ x 2HU x 261 mm (482.6 x 89.9 x 261 mm) / (19.02 x 3.54 x 10.28 in.)
|
|
Weight
|
PRO-DAR4 PRO-DAR8 : Approx. 3.1 kg. / 6.83 lb.PRO-DAR12 PRO-DAR16 : Approx. TBD kg. / TBD lb.
|
|
Alarm Connector
|
3-pole Phoenix terminal block/header |
Ordering Codes
| Model |
Product No. |
|
Receiver Multicoupler family with redundant amplifier system for the VHF & the low UHF range 30 – 960 MHz. |
PRO-DAR |
PROCOM A/S reserves the right to
amend specifications without prior notice
PROCOM A/S • Smedetoften 12
DK 3600 Frederikssund • Denmark
Generated : 2026-06-22
Version 1