Block Diagram
| Electrical | |
| Model | PRO-PHY 380-2700-3 dB-… |
|---|---|
| Frequency | 380 – 2700 MHz |
| Max. Input Power | 100 W per port, when used as a combiner 200 W on one port, when used as a splitter |
| Insertion Loss | Port 1 to 2 or 1 to 3 : 3.5 dB ±1 dB |
| Impedance | 50 Ω |
| Isolation | 380 – 960 MHz : > 20 dB 960 – 2100 MHz : > 15 dB 2100 – 2700 MHz : > 20 dB |
| VSWR | < 1.5:1 |
| Passive Intermodulation | < -130 dBc (2 x 43 dBm) |
| Environmental | |
| Operating temperature range | -30 °C to +60 °C |
|---|---|
| Ingress Protection | IP67 |
| Mechanical | |
| Compliance | RoHS |
|---|---|
| Connection(s) | N(f), 4.3/10(f) or 7/16 DIN(f) |
| Historic Brand | Amphenol Procom |
| Dimensions | 125.6 x 99.6 x 46.1 mm / 4.94 x 3.92 x 1.81 in. (incl. connectors and flanges) |
| Weight | Approx. 0.865 kg / 1.91 lb. |
| Mounting | 5.2 mm / 0.205 in. dia. (4 holes) |
| Model | Product No. | Model |
|---|---|---|
|
PRO-PHY 380-2700-3 dB-N(f) |
200002403 | PRO-PHY 380-2700-3 dB-N(f) |
|
PRO-PHY 380-2700-3 dB-4.3/10(f) |
200002762 | PRO-PHY 380-2700-3 dB-4.3/10(f) |
|
PRO-PHY 380-2700-3 dB-7/16(f) |
200002408 | PRO-PHY 380-2700-3 dB-7/16(f) |
Coupler splitter mode:
Divides the signal into two equal components with a 90˚; phase difference that can be used to split signals from tower top amplifiers to the base station receivers.
Coupler combiner mode 1:
If the same signals is applied at the input ports with a 90˚; phase difference the signals adds up on one port.
Coupler combiner mode 2:
Combining two non-coherent signals that are available at both ports.
All dimensions are given in mm [in.]