PRO-DAR

Receiver Multicoupler family with redundant amplifier system for the VHF & the low UHF range 30 – 960 MHz.

Find Out More
Electrical
Power Supply 230 V AC models :
198 to 264 V AC 47 – 63 Hz / Max. 0.16 A
115 V AC models :
99 to 132 V AC 47 – 63 Hz / Max. 0.32 A
Model
PRO-DAR4 & PRO-DAR8PRO-DAR12 & PRO-DAR16 (Ask for availability)
Gain (Input To All Outputs) 2 dB nominal
Frequency 30 – 960 MHz
Gain variance < ±2.0 dB
Max. Output Power @ 1 dB Compression (P1dB) > 10 dBm
Noise Figure, Amplifier 30 – 520 MHz : < 3.0 dB
520 – 960 MHz : < 3.5 dB
Output 3. Order Intercept point (OIP3) 30 – 520 MHz : > 30 dBm
520 – 960 MHz : > 25 dBm
Impedance 50 Ω
Output 2. Order Intercept point (OIP2) > 45 dBm
Max. Input Power (dBm) 23 dBm
Isolation between outputs 30 – 100 MHz : > 20 dB
100 – 400 MHz : > 27 dB
400 – 960 MHz : > 20 dB
Input VSWR ≤ 2.0:1
Input-Output Isolation > 30 dB
Effective Noise Figure all outputs < 5 dB
Output VSWR ≤ 1.5:1
DC Supply, 12 V DC types 10.8 to 14.4 V DC / 600 mA
DC Supply, 24 V DC types 20 to 33 V DC / 600 mA
DC Supply, 48 V DC types 40 to 60 V DC / 125 mA
No. of channels
4 or 812 or 16
Environmental
Operating temperature range -10 °C to +60 °C
Humidity < 90% non-condensing
Mechanical
Power Connector 3-terminal IEC60320-1 C14 (m)
Connection(s) N(f) (standard)
BNC(f), TNC(f) or SMA(f), please contact for availability
DC Connector 3-pole Phoenix terminal block/header
Historic Brand Amphenol Procom
Dimensions
PRO-DAR4 & PRO-DAR8 :
19″ x 1HU x 261 mm (482.6 x 44.45 x 261 mm) /
(19.02 x 1.75 x 10.28 in.)
PRO-DAR12 & PRO-DAR16 :
19″ x 2HU x 261 mm (482.6 x 89.9 x 261 mm) /
(19.02 x 3.54 x 10.28 in.)
Weight
PRO-DAR4 PRO-DAR8 : Approx. 3.1 kg. / 6.83 lb.PRO-DAR12 PRO-DAR16 : Approx. TBD kg. / TBD lb.
Alarm Connector 3-pole Phoenix terminal block/header
  • Active Receiver multicouplers PRO-DAR (Dual Amplifier RMC) comes with 1 antenna input and 4 or 8 receiver outputs. The PRO-DAR’s with 12 or 16 outputs are under development.
  • Allows a number of receivers to share the same antenna without interaction and loss of signal.
  • Coves the whole frequency range 30 to 960 MHz.
  • If only a smaller frequency range is desired, a preselector filter can be built in to prevent possible interference from strong transmitters outside the frequency band of interest. Amphenol Procom offer a wide range of both band selective and narrow-band low-loss filters suitable for preselector use.
  • Please refer to the preselector overview and specify frequency range when ordering.
  • The build-in ultra-high dynamic range amplifiers ensure outstanding multicoupler linearity and high reject of distortion products.
  • Low amplifier noise figure ensures lowest possible S/N deterioration of the received and distributed RF signals.
  • Redundant amplifier design with two identical amplifier stages coupled in parallel ensures maximum operational reliability.
  • If a fault occurs in one amplifier stage,the amplifier will continue to operate with gain around -6 dB relative to the normal gain providing uninterrupted service with only minor performance deterioration.
  • High isolation between receiver outputs ensure insignificant low mutual coupling between the connected receivers.
  • Operates on 230 V AC or 115 V AC mains supply or 12 V, 24 V or 48 V DC supply (Depending on type, see ordeing designations)
  • Galvanically isolated power supply with floating power supply input prevents unwanted ground loops and ensures operation on DC voltage systems with both + and – to ground.
  • Power supply backup function provides automatic switching to DC supply if the AC mains supply fails, ensuring uninterrupted service of the multicoupler.
  • POWER ON/operating status LED on front.
  • Supply voltage/current monitoring alarm circuitry with floating relay switch-over alarm contact. If a fault occurs, in the RF amplifer circuitry, the alarm circuitry immediately toggles the relay to indicate fault condition and change the POWER on/operating status LED from constant green light to flashing red light.
  • If both mains AC supply and DC supply fail, the multicoupler is completely de-energized, the relay will also be toggled to indicate fault condition. The POWER ON / operating status LED will then be off in this situation.
  • Mains supply connector: IEC type fitted with noise filter.
  • DC power supply connector: Pluggable terminal block/header fitted with noise filter.
  • Alarm connector: Pluggable terminal block/header.
  • RF connectors: N-female on all ports (other types on request).
  • Comes as standard with black powder lacquered front plate
  • 19” rack module housing
  • PRO-DAR4 & PRO-DAR8: 1HU
  • PRO-DAR12 & PRO-DAR16: 2HU (Under development)
  • Please Note:
  • Power cable is not included. Must be ordered separately, see Accessories.

No content found

This product doesn’t have any diagrams yet.

Model Product No. Add To Quote
Receiver Multicoupler family with redundant amplifier system for the VHF & the low UHF range 30 – 960 MHz. PRO-DAR

Login required

You need to be logged in into your account to view downloadable documents.

Ordering designations

Contact for system-specific product no.

Use the guide below to make the name of the PRO-DAR you would like to buy. Remember to buy the Power cable separately if needed.

ModelNo. of outputs    AC PowerDC PowerAntenna ConnectorRx ConnectorNumber of loadsPreselector filter
 PRO-DAR 4 outputs = 4
8 outputs = 8
12 outputs = 12***
16 outputs = 16***
230V AC = -230 V
115V AC = -115 V
12V DC = /12 V
24V DC = /24 V
48V DC = /48 V
N-female = -N
TNC-female = -TNC
BNC-female = -BNC
SMA-female = -SMA
N-female = /N
TNC-female = /TNC
BNC-female = /BNC
SMA-female = /SMA
No load = blank *
One 1W load = -1L
Two 1W loads = -2L
Three 1W loads = -3L
No filter = blank
See tables with
preselectors below
Naming Example       
PRO-DAR 8 -230V /12V -N /N -1L BPF 118-137-C

Naming Example: PRO-DAR8-230V/12V-N/N-1L BPF 118-137 C

   * Terminating unused ports will secure the electrical performances of the RMC.
  ** “Blank” means sign omitted.
  ***Ask for availability

Accessories
 ModelProduct No.
Power Cable EU , with Ground 210002646
Power Cable UK , with Ground 210002647
Power Cable US , with Ground 210002648
Model Housing

PRO-DAR4-N & PRO-DAR8-N
PRO DAR

 

PRO-DAR8-N – Rear side
PRO DAR8 N Rear side

PRO-DAR12-N & PRO-DAR16-N
PRO DAR12 N PRO DAR16 N 2

 

PRO-DAR12-N & PRO-DAR16-N – Rear side
Image Coming Soon

Low-Loss Preselector Filters for PRO-DAR, Overview

Band selective standard blackbox filters (other filters on request)

TYPE DESIGNATIONFILTER TYPEPASS BAND FREQUENCY RANGE
BPF 66-88 Band pass  66 – 88 MHz
BPF 88-108 Band pass  88 – 108 MHz
BPF 112-136 Band pass 112 – 136 MHz
BPF 118-137 Band pass 118 – 137 MHz
BPF 118-174 Band pass 118 – 174 MHz
BPF 136-225 Band pass 136 – 225 MHz
BPF 146-174 Band pass 146 – 174 MHz
BPF 225-400 Band pass 225 – 400 MHz
BPF 300-500 Band pass 300 – 500 MHz
BPF 800-1000 Band pass 800 – 1000 MHz
LP 174-FME Low pass    0 – 174 MHz
HP 380-FME High pass 380 – 1000 MHz

Steep sided standard BP filters:

TYPE DESIGNATIONFILTER TYPEPASS BAND FREQUENCY RNGESTOP BAND FREQUENCY RANGE
PRO-BPF 118-144 XS (Please contact for availabilty) Band pass 118 – 144 MHz 0 – 108 MHz and 155 – 1000 MHz
PRO-BPF 225-380 XS (Please contact for availabilty) Band pass 225 – 380 MHz 0 – 200 MHz and 410 – 1000 MHz
PRO-DBPF 118-144/225-380 XS (Please contact for availabilty) Dual Band pass 118 – 144 MHz and 225 – 380 MHz 0 – 108 MHz, 155 – 200 MHz and 410 – 600 MHz

Narrow band standard BP filters:

TYPE DESIGNATIONFILTER TYPECENTER FREQUENCY -1 dB BANDWIDTH
BPF 4/4-[BW] Band pass To be ordered within 66 – 88 MHz To be specified as 2, 4 or 6 MHz
BPF 3/4 Band pass To be ordered within 112 – 136 MHz 1.5 MHz
BPF 2/4-[BW] Band pass To be ordered within 144 – 175 MHz To be specified as 2, 4 or 6 MHz
BPF 70/4-HX Band pass To be ordered within 380 – 470 MHz To be ordered within 3 – 15 MHz
BPF 900/4 Band pass To be ordered within 820 – 960 MHz Typ. 7 MHz
EU and UK Declaration of Conformity

Hereby Amphenol Procom declare that the product type PRO-DAR is in compliance with EU Directive 2014/53/EU and
the UK Radio Equipment Regulations 2017 (S.I. 2017 No. 1206).
The full text of the Declaration of Conformity is available at:

https://amphenolprocom.com/images/shop/catalog/pdf-for-catalouges/Declaration-of-Conformity-PRO-DAR.pdf